Related Products:


Privacy Policy | Careers | Refer a Colleague
Sensor Unit
   
Type
Canon? Medical CXDI-50G Sensor
Imaging Area
35.6 cm x 43.2 cm (14" x 17")
Pixel Pitch
160 x 160 microns
Pixel Array
2,208 x 2,688 pixels (5,935,104 pixels)
Grayscale
12 bit (4,096 levels), 14 bit A/D
Weight
4.8 kg (10.6 lbs.)
 
System
 
Controls
Flat panel operators’ touch panel display screen
Application
Veterinary-specific anatomical view selection and acquisition optimization
Image Processing Time
Preview: approx. 4 seconds after exposure
Canon’s world-class patented multi-frequency image enhancement suite standard
Data Output
DICOM 3.0 COMPLIANT
100BaseT network interface
Networks to Eklin RapidView™ diagnostic workstations,
Eklin RapidStore™ multi-modality PACS image management systems,
Eklin.Net web-based image management portal, and medical-grade
dry film printers (available from Eklin)
Image Storage
Local storage included in control workstation (approx. 3,000 images)
Long term storage provided by external workstation or PACS archive
Voltage
100V/120V, 230/240V (50/60Hz)
Power Consumption

300 VA Maximum

 

Operating Environment
5-35 °C (41-95 °F)
30-75% RH (non-condensing)
*Professional installation by Eklin required
 

Sensor Unit
Type Sensor
Imaging Area 35.6 cm x 43.2 cm (14" x 17")
Pixel Pitch 160 x 160 microns
Pixel Array 2,208 x 2,688 pixels (5,935,104 pixels)
Grayscale 12 bit (4,096 levels). 14 bit A/D
Weight 4.8 kg (10.6 lbs.)
System
Controls Flat panel operators' touch panel display screen
Application Veterinary-specific anatomical view selection and acquisition optimization
Image Processing
Time
Preview: approx. 4 seconds after exposure
Total time: approx. 20 seconds per image
Data Output DICOM 3.0 COMPLIANT
100BaseT network interface
Networks to Eklin RapidView™ diagnostic workstations, Eklin RapidStore™ multi-modality PACS image management systems, Eklin.Net web-based image management portal, and medical-grade dry-film printers (available from Eklin)
Image Storage Local storage included in control workstation (approx. 3,000 images)
Long term storage provided by external workstation or PACS archive
Voltage 100V/120V, 230/240V (50/60Hz)
Power Consumption 300 VA Maximum
Operating
Environment
5-35° C (41-95° F)
30-75% RH (no condensation)

* professional installation by Eklin required

Featuring the industry's leading DR sensor

  • Human medical quality - FDA cleared
  • Full 14"x17" detection area
  • Unparalleled technology with the largest DR market share
  • Outstanding contrast resolution

Accessory 1

Short description of this accessory (ideally 1-2 lines in length).
more info

Accessory 2

Short description of this accessory (ideally 1-2 lines in length).
more info

Accessory 3

Short description of this accessory (ideally 1-2 lines in length).
more info

Accessory 4

Short description of this accessory (ideally 1-2 lines in length).
more info

Accessory 5

Short description of this accessory (ideally 1-2 lines in length).
more info